Uslex (Diskussion | Beiträge) Die Seite wurde neu angelegt: „If a signal controls only a single LED, you can specify which of the two contacts this is in the connection settings under the Connection tab, or deactivate the unused contact. Two such signals can thus share a single output of an address. Dr. Railroad will issue a warning, but this can be ignored if you know what you are doing.“ |
Uslex (Diskussion | Beiträge) Die Seite wurde neu angelegt: „In TrainController Gold, the two outputs of a symbol that occupies more than two contacts can also be freely assigned. The associated accessory can therefore be connected to any two pairs of contacts.“ |
||
| Zeile 38: | Zeile 38: | ||
If a signal controls only a single LED, you can specify which of the two contacts this is in the connection settings under the Connection tab, or deactivate the unused contact. Two such signals can thus share a single output of an address. Dr. Railroad will issue a warning, but this can be ignored if you know what you are doing. | If a signal controls only a single LED, you can specify which of the two contacts this is in the connection settings under the Connection tab, or deactivate the unused contact. Two such signals can thus share a single output of an address. Dr. Railroad will issue a warning, but this can be ignored if you know what you are doing. | ||
In TrainController Gold, the two outputs of a symbol that occupies more than two contacts can also be freely assigned. The associated accessory can therefore be connected to any two pairs of contacts. | |||
In TrainController Gold | |||
<div lang="de" dir="ltr" class="mw-content-ltr"> | <div lang="de" dir="ltr" class="mw-content-ltr"> | ||
Version vom 15. Dezember 2025, 13:13 Uhr
ZIMO MX8S
Daylight signals
Wie wird in TrainController ein ZIMO MX8S-Modul mit 32-Einzelfunktionen, also 32 LED's für Tageslichtsignale konfiguriert?
Ausgang eines Schaltsymbols
Herr Freiwald schreibt dazu in diesem Beitrag:
Ein Ausgang eines Schaltsymbols im Sinne von TrainController steuert normalerweise immer 2 Kontakte des entsprechenden Decoders an. Die 16 Ausgänge in TrainController für ein MX8 können also 16*2=32 Kontakte ansteuern.
Contacts 1 and 2 on the MX8 correspond to output 1 in TrainController. Contacts 3 and 4 on the MX8 correspond to output 2 in TrainController. ... Contacts 31 and 32 on the MX8 correspond to output 16 in TrainController.
Controlling outputs individually
To control individual LEDs, symbols for push buttons or on/off switches are used.
With these symbols, in addition to the address and the output (remember: one output corresponds to two contacts), you can select whether the symbol should control contact 1 or contact 2 of this pair. Two pushbuttons or on/off switches can therefore share one output (one contact pair).
If a signal controls only a single LED, you can specify which of the two contacts this is in the connection settings under the Connection tab, or deactivate the unused contact. Two such signals can thus share a single output of an address. Dr. Railroad will issue a warning, but this can be ignored if you know what you are doing.
In TrainController Gold, the two outputs of a symbol that occupies more than two contacts can also be freely assigned. The associated accessory can therefore be connected to any two pairs of contacts.
Sind die drei oder vier Kontakte eines Signals allerdings völlig frei verteilt, so muss man diese einzeln mit Tastern oder Ein-/Ausschaltern ansteuern, welche wiederum indirekt über Bahnwärter mit einem Signalsymbol verknüpft werden. Das Signalsymbol wird dann auf Ohne Anschluss gesetzt. Auf diese Weise kann das Signalsymbol indirekt bis zur 4 LEDs ansteuern, die beliebig auf die Kontakte von einem oder mehreren MX8-Modulen verteilt sind. Besser ist es aber, Ordnung in der Verkabelung zu halten und die Kontakte, die zu einem Zubehör gehören, zusammen zu lassen.
Option Impuls ausschalten
Da hier offenbar Signalbirnchen bzw. LEDs dauerhaft eingestellt werden sollen, muss die Option Impuls ausgeschaltet werden (siehe Option Hilfe zu dieser Registerkarte).
Die Option Impuls hingegen beschreibt bei einem Signal oder einer Weiche, welche beide Kontakte des Ausgangs belegt (Normalfall), ob beim Umschalten von einem Kontakt auf den anderen der neue Kontakt nur kurzzeitig (Impuls) oder dauerhaft eingeschaltet werden soll.
Weblinks
- Quelle: Forum
- --Wohlmannstetter 16:16, 2. Jan. 2012 (CET)
- bearbeitet: Uslex 11:02, 9. Jun. 2022 (CEST), Uslex (Diskussion) 13:09, 15. Dez. 2025 (UTC)