Spontanfahrt mit zufälligem Halt/en: Unterschied zwischen den Versionen

Aus RailRoad&Co.-Wiki
Zur Navigation springenZur Suche springen
Die Seite wurde neu angelegt: „It is important to note that the value must be fixed '''before the block''' with the variable stay is '''reserved'''. Therefore, with a reservation lance of 2, the value must be set 3 blocks before the stay.“
Die Seite wurde neu angelegt: „'''Or in other words:''' The value used is the one that is current at the moment the block is reserved.“
Zeile 34: Zeile 34:
It is important to note that the value must be fixed '''before the block''' with the variable stay is '''reserved'''. Therefore, with a reservation lance of 2, the value must be set 3 blocks before the stay.
It is important to note that the value must be fixed '''before the block''' with the variable stay is '''reserved'''. Therefore, with a reservation lance of 2, the value must be set 3 blocks before the stay.


<div lang="de" dir="ltr" class="mw-content-ltr">
'''Or in other words:''' The value used is the one that is current at the moment the block is reserved.
'''Oder anders:''' Es wird der Wert genutzt, der im Moment der Reservierung des Blockes aktuell ist.
</div>


<div lang="de" dir="ltr" class="mw-content-ltr">
<div lang="de" dir="ltr" class="mw-content-ltr">

Version vom 8. April 2026, 16:55 Uhr

Verwendung
thumbs


Spontaneous trip with a random stop

Train should not always stop

The idea is not that every train should stop, but rather that trains should stop at random.

Insert time variable

I created a global variable of type Number. Then the variable "Stay_Random" is assigned a starting value of 0.

There is a 50% probability that it will be increased to 7000 (7000 milliseconds = 7 seconds).

This variable is then entered as the length of stay.

Fig: Random stop - spontaneous trip

Problem: The result was that the test locomotive always stopped one lap later, even though (according to the variable monitor) the value of the variable was 7000.

Define variable in time

Silvio Richter describes the solution in the forum:

It doesn't matter which means (macro, section settings, etc.) are used to set the variable value.

It is important to note that the value must be fixed before the block with the variable stay is reserved. Therefore, with a reservation lance of 2, the value must be set 3 blocks before the stay.

Or in other words: The value used is the one that is current at the moment the block is reserved.



-- Uslex 16:19, 8. Apr. 2026 (CEST)